Pressure Spring Type Overhead Line Fault Indicator With LED

Chat Now
Product Details

Quick Details

Model Number: CBDL-JDG  

Joint Type: Pressure Spring Type  

Application: Overhead 6-35KV High Voltage Cable 

IP Code: IP65   

Use: Widely used in overhead lines.

Fault indication: In normal operation, the window is displayed in white; when a short circuit or ground fault occurs, the window is displayed in red (or the indicator light flashes).

Automatic reset: The fault indicator will be automatically reset. The reset time can be selected by the customer according to the line environment, the length of the line, and department requirements.


Pressure Spring Type Overhead Line Fault Indicator With LED is installed on the 6-35KV transmission and distribution line to indicate the fault current circulation. This new type of fault indicator not only detects short-circuit faults and ground faults on the line, but also selects the flop or illuminate alarm by its own judgment. If the fault occurs at night, it chooses to illuminate the alarm; if the fault occurs during the day, it chooses the flop alarm. If the line fails, the line patrol personnel can quickly determine the fault zone and find the fault point by means of the red alarm display of the indicator, which greatly improves the work efficiency, shortens the power outage time, and effectively improves the reliability of the power supply. It can accurately judge the fault line and fault point, and has the characteristics of stable performance, high precision, anti-interference ability, beautiful appearance and convenient installation. It is not affected by line magnetizing inrush current, higher harmonics, current fluctuations, and cable distribution capacitor bypass.


 Function and Benefit
◆Indicate the fault line and fault point quickly, lessen the blackout area;
◆Shorten troubleshooting time,improving electricity and power supply reliability;
◆Accurately indicate the instant fault, which is conducive to rule out the power supply problems;
◆Providing technical means for find the hidden permanent fault point;
◆Shorten the search time to find the fault point, reduce the labor intensity of line patrol person;
◆Defining the responsibility of the fault area and responsible people;
◆Avoiding traditional multiple switch out,switch on,line patrol to the effects of power equipment.
 

 Technical Parameters 

◆Applicable voltage grade: U≥6-35KV
◆Applicable wire current:  I≤1200A
◆Applicable wire diameter: 16mm sq≤D≤240mm sq
◆Action response time: 0.06s≤t≤3s
◆Reset time: 6,12,24,48H (Selectable, Default 24H)
◆Ambient temperature: -35℃≤T≤+70℃
◆Operation times: ≥5000Times
◆Static power loss: ≤10μW
◆Protection class: IP65


 Action principle
Grounding detection principle: the first half of the capacitor current at the sampling grounding moment and the first half of the voltage at the grounding instant, compare the phase, when the capacitance current at the sampling grounding moment is abrupt and larger than a certain value, and is in phase with the first half of the voltage at the grounding instant, At the same time, the voltage of the wire to the ground is lowered, and it is judged that the line is grounded, otherwise the line is not grounded.

Short circuit detection principle: According to the phenomenon of short circuit,the current break when  short circuit happen, the action on the basis of the protection movement power outages.
Used to judge the short circuit fault indicator diagram
图片1.png  
As line 2# B phase 2,5,8 indicator and line 2# C phase 3,6,9 indicator turn red, but the 11,12 indicator still show white, that judged the point D happen short circuit
Used to judge the grounding fault indicator diagram:
图片2.png  
As line 2# C phase 3,6,9 indicator turn red,but the 12 indicator still show white, that judged the point D happen grounding fault.

 

Products Type:

图片4.jpg  

Test Report:
Our products have already passed the test by CMA, CNAS,CE till now, and we also have ability to arrange other relevant testing and factory audit as your requirement.

图片6.jpg  

Certificate: 

图片7.png  

Company:
图片8.png 


Feedback